Specifications
Installation and Operation Manual Chapter 1 Introduction
LA-210 Ver. 1.5 Technical Specifications 1-17
Ethernet physical layer statistics and frame counters
Ethernet Ports
Interface
10/100BaseT
Connectors
1 or 4 RJ-45
Timing
Receive, derived from the SHDSL received signal (CPE
unit)
Diagnostics
Tests
Ping, trace route
Indicators
(Front Panel)
PWR (green)
On: LA-210 is powered on
Off: LA-210 is off
TST (yellow)
On: Active test
Off: No test
SHDSL SYNC
(green/red)
Blinking (green/red): At least one line is synchronized
and at least one line is in process.
On (orange): At least one line is synchronized and all
others remain unsynchronized and are not in process.
On (green): All lines are synchronized
Blinking (red): No line is synchronized and at least one
line is in process.
On (red): No line is synchronized.
ALM (red)
On: A new alarm is detected in the alarm buffer
Off: No alarm currently detected
Indicators
(Rear Panel)
Ethernet Ports
LINK/ACT
(green/yellow)
On (green): Ethernet link is up
Off: Ethernet link is down
Blinking (yellow): Data is being transferred
Power Source
AC/DC Voltage
Wide-range: 100–240 VAC, 50/60 Hz or
48/60 VDC nominal (40–72 VDC)
Estimated Power
Consumption
(4-Port Unit)
2-wires: 5.9W
4-wires: 6.5W
8-wires: 7W