Specifications
Installation and Operation Manual Chapter 6 Diagnostics and Troubleshooting
LA-210 Ver. 1.5 Testing the Unit 6-27
³ To trace OAM monitoring statistics according to the Remote MEP IDs:
1. From the OAM Tests menu (Diagnostics > OAM Tests), select Loopback.
The Loopback menu appears as illustrated in .
2. Set Destination Type to Remote MEP ID.
Remote MEP parameters appear as illustrated in
Figure
6-26
.
3. Define the test parameters according to
Table
6-20
.
LA-210
Main Menu > Diagnostics > OAM Tests > Loopback
1. Flow ID[1 - 8] ... (1)
Flow Name ... (No such flow)
2. Destination Type (Remote MEP ID)
3. Remote MEP ID[1 - 65535] ... (0)
Remote MEP Address ... (00-00-00-00-00-00)
4. Number of LBs to Send[0 - 50] ... (0)
ESC-Previous menu; !-Main menu; &-Exit; ?-Help
Figure
6-28. Loopback Menu – Remote MEP ID
Table
6-20. Loopback Menu – Remote MEP ID
Parameter Possible Values Remarks
Flow ID 1 – 8 The ID of the virtual Ethernet connection.
Flow Name
The name of the virtual Ethernet connection you chose.
Note: This parameter is Read Only and cannot be configured.
Destination Type Destination Address
Remote MEP ID
The destination type for the OAM test
Default: Destination Address
Remote MEP ID 0 – 65535 ID of the remote maintenance endpoint, terminating the
maintenance entity. It must be different from the local MEP ID
and unique for the maintenance domain. If set to 0, no
maintenance end point (MEP) is assigned.
Default: 0
Remote MEP
Address
The MAC address of the device assigned as media point at the
remote location.
Number of LBs
to Send
0 – 50 The number of loobacks.
Default: 0