Specifications

Chapter 6 Diagnostics and Troubleshooting Installation and Operation Manual
6-26 Testing the Unit LA-210 Ver. 1.5
OAM Tests
This diagnostic utility traces the OAM monitoring statistics on selected virtual
Ethernet connections (Flows). You may trace the OAM monitoring statistics
according to the destination address or the maintenance end point (MEP)`.
³ To trace OAM monitoring statistics according to the destination address:
1. From the OAM Tests menu (Diagnostics > OAM Tests), select Loopback.
The Loopback menu appears as illustrated in
Figure
6-25
.
2. Verify that Destination Type is set to Destination Address.
3. Define the test parameters according to
Table
6-19
.
LA-210
Main Menu > Diagnostics > OAM Tests > Loopback
1. Flow ID[1 - 8] ... (1)
Flow Name ... (No such Flow)
2. Destination Type (Destination Address)
3. Destination Address ... (00-00-00-00-00-00)
4. Number of LBs to Send[0 - 50] ... (0)
ESC-Previous menu; !-Main menu; &-Exit; ?-Help
Figure
6-27. Loopback Menu – Destination Address
Table
6-19. Loopback Menu – Destination Address
Parameter Possible Values Remarks
Flow ID 1 – 8 The ID of the virtual Ethernet connection.
Flow Name The name of the virtual Ethernet connection you chose.
Note: This parameter is Read Only and cannot be configured.
Destination Type Destination Address
Remote MEP ID
The destination type for the OAM test
Default: Destination Address
Destination
Address
The MAC address of the destination device
Number of LBs
to Send
0 – 50 The number of loobacks.
Default: 0