Specifications

Chapter 6 Diagnostics and Troubleshooting Installation and Operation Manual
6-24 Testing the Unit LA-210 Ver. 1.5
6.4 Troubleshooting
Use the chart shown in
Table
6-18
to identify and remedy problems in unit
operation.
Table
6-18. Troubleshooting Chart
Fault Probable Cause Remedial Action
Power LED is off No power supplied to unit Check power source.
Check power cable connected and
correctly wired.
Ethernet Link LED is off No Ethernet Link detected
Ethernet port in switch and LA-210
are not in the same rate or duplex
mode
Check cable connected and
correctly wired.
Check switch and LA-210 Ethernet
port configuration (negotiation,
rate, duplex mode).
Use Event Log File to check events.
No traffic flow between
two units
Configuration or logical layer problems Use System Interface Status screen
for assistance. All active ports that
show Activation–Up, should show
Operation–Up.
Use Event Log File to check events.
Check LA-210 configuration and, if
necessary, other LA-210
parameters.
Partial Traffic Flow Timing configuration is not
properly set
Check timing settings.