Specifications
Installation and Operation Manual Chapter 5 Configuring a Flow-Based Point-To-Point Application
LA-210 Ver. 1.5 Configuring the Units for Advanced Configurations 5-17
³ To bind a BW profile to Service777_pbit_4:
1. Return to the CoS menu and press <F> or <B> to navigate to
Service7775_pbit_4.
2. In the associated CoS menu, select Ingress BW Profile.
The ingress BW profile appears.
LA-210
..>Applications>Flows>Flow Definition>CoS>Ingress BW Profile (Undefined)
1. Undefined
2. DefaultIngressBW1
3. BW_for_Service777
4. BW_for_Service555
>
ESC-prev.menu; !-main menu; &-exit 1 M/ 1 C
Figure
5-30. Ingress BW Profiles
3. Select BW_for_Service777.
The BW profile is bound to Service777_pbit_4 (
Figure
5-29
).
4. Press <S> to save the settings.
LA-210
Configuration>Applications>Flows>Flow Definition>CoS
(Flow 1 UNI ETH-1)
1. ID[0 - 7] ... (3)
2. Name ... (Service777_pbit_4)
3. Ingress BW Profile > (BW_for_service_777)
>
a-Add; f-Forward; b-Backward; d-Delete
ESC-prev.menu; !-main menu; &-exit 1 M/ 1 C
Figure
5-31. Ingress BW Profile BW_for_service_777 bound to Service777_pbit_4
Configuring the DSLAM
The DSLAM configuration has to match the configuration of the LA-210 units with
the difference that the clock mode is configured to Central mode.