Specifications
Installation and Operation Manual Chapter 5 Configuring a Flow-Based Point-To-Point Application
LA-210 Ver. 1.5 Configuring the Units for Basic Applications 5-3
Table
5-1. System Configuration Summary
Device Host IP IP mask Default Gateway
LA-210 172.17.182.23 255.255.255.0 172.17.182.1
DSLAM 172.17.182.22 255.255.255.0 172.17.182.1
ETX-202 (Client) 172.17.182.25 255.255.255.0 172.17.182.1
ETX-202 (Server) 172.17.182.24 255.255.255.0 172.17.182.1
Table
5-2. Flow Configuration Summary – LA-210
Flow Interface Flow ID CE-VLAN-ID Flow Interface SP-VLAN-ID
ETH-1 1 555
777
UNI ETH-1 10
Table
5-3. Configuration Summary – ETX-202 (Client and Server)
Interface Host Tagging Host VLAN ID Port/Stacking VID Tag Handling
User 1 Tagged 555 555
777
Stack
User 2 Tagged 555 555
777
Stack
Accessing ETX-202 and LA-210 Units
This section instructs you on accessing the LA-210 and ETX-202 units using the
terminal application.
³ To log on:
1. Configure the parameters of your terminal application as listed below.
Baud rate: 9600
Data bits: 8
Stop bits: 1
Parity: None
Flow Control: None
2. If not already done, connect a serial cable to the respective unit’s Control
port and your PC’s COM port.
3. Press <Enter>.
You are asked for the user name and the password.
4. Enter the user name for Super User and the associated password. The default
user name is su and the default password is 1234.
The respective unit’s main menu appears.