Specifications
IPmux-11 Installation and Operation Manual Appendix D Configuration Menus
Configuring IPmux-11 at the Physical Level D-13
Configuration>Physical layer>TDM (E1) configuration
Channel ID (1)
Restoration time >(CCITT)
Signaling mode (CAS Disabled)
1. Admin status (Enable)
2. Transmit clock source >(Adaptive)
3. Rx sensitivity (Short haul)
4. Line type >(Framed G.704)
5. Idle code[0 - ff] ... (7E)
6. Send upon fail (OOS Code)
(N)
>
Please select item <1 to 11>
ESC-prev.menu; !-main menu; &-exit 1 Mngr/s
Figure D-17. TDM (E1) Configuration Menu (Page 1)
Configuration>Physical layer>TDM (E1) configuration
...(P)
7. OOS Code[0 - ff] ... (FF)
8. OOS signaling > (Space)
9. Mark signaling code[0 - f] ... (D)
10. Space signaling code[0 - f] ... (1)
>
Please select item <1 to 11>
ESC-prev.menu; !-main menu; &-exit 1 Mngr/s
Figure D-18. TDM (E1) Configuration Menu (Page 2)
Configuring the T1 TDM Interface
The procedure for configuring the T1 port is similar to the procedure described
above for configuring the E1 port. The following parameters are unique to the T1
links:
• Line type (T1 framing mode):
Esf (24 frames per multiframe)
SF (D4) (12 frames per multiframe)
• Line code (line code and zero suppression method used by the port):
B7ZS
B8ZS
AMI