Specifications

Appendix D Configuration Menus IPmux-11 Installation and Operation Manual
D-10 Configuring System Parameters
Control Port Parameters
Configuration parameters of the IPmux-11 control port are set at the factory and
cannot be changed by the user (see Figure D-14). These parameters have the
following values:
Baud rate – 155200 baud
Data bits – 8
Parity – None
Stop bits – 1
Flow control – None.
Configuration>System>Control port
Baud rate (bps) > (115200)
Data bits (8)
Parity > (None)
Stop bits (1)
Flow control > (None)
>
Please select item <1 to 1>
ESC-prev.menu; !-main menu; &-exit 1 Mngr/s
Figure D-14. Control Port Screen
Setting Date and Time
You can set the time for the IPmux-11 internal real-time clock.
To set date and time:
1. From the System menu (Figure D-5), select Date/time.
The Date/Time menu appears (see Figure D-15).
2. From the Date/Time menu, select Set time, and enter the current time in the
hh:mm:ss format.
3. Select Set date, and enter the current date in the yyyy:mm:dd format.
Configuration>System>Date/time
1. Set time <HH:MM:SS> ... (09:12:06)
2. Set date <YYYY-MM-DD> ... (2004-01-18)
>
Please select item <1 to 2>
ESC-prev.menu; !-main menu; &-exit 1 Mngr/s
Figure D-15. Date/Time Menu