Specifications
IPmux-11 Installation and Operation Manual Chapter 2 Installation and Setup
Installation and Setup 2-3
To connect the unbalanced E1 interface:
1. Connect the RJ-45 connector of the adapter cable to the RJ-45 port designated
E1.
2. Connect the transmit cable to the red coaxial connector of the adapter cable
marked ↑.
3. Connect the receive cable to the green coaxial connector of the adapter cable
marked ↓.
Connecting the Power
IPmux-11 is equipped with a dual input AC/DC power supply. AC or DC power is
supplied to IPmux-11 via a standard 3-prong power input connector on the rear
panel (see Figure 2-1).
Before switching on this unit and connecting or disconnecting any other cable,
the protective earth terminals of this unit must be connected to the protective
ground conductor of the mains (AC or DC) power cord. If you are using an
extension cord (power cable) make sure it is grounded as well.
Any interruption of the protective (grounding) conductor (inside or outside the
instrument) or disconnecting of the protective earth terminal can make this
unit dangerous. Intentional interruption is prohibited.
Connecting AC Power
AC power should be supplied through the 1.5m (5 ft) standard power cable
terminated by a standard 3-prong plug. The cable is provided with the unit.
To connect AC power:
1. Connect the power cable to the power connector on the IPmux-11 rear panel.
2. Connect the power cable to the mains outlet.
The unit turns on automatically upon connection to the mains.
Connecting DC Power
DC power is supplied to IPmux-11 via compatible AC/DC plug for attaching DC
power supply lines.
To connect DC power:
• Refer to the DC power supply connection supplement.
Warning