Specifications
IPmux-11 Installation and Operation Manual Chapter 1 Introduction
Technical Specifications 1-21
Timing
Sources
• Internal
• External (E1 or T1, via dedicated connector)
• Loopback
• Adaptive
Bundles
Number of TDM
Bytes
48–1440 TDM bytes per Ethernet frame
Destination IP
Address
User-configurable
Jitter Buffer Size
3–300 msec
Management
Terminal
Interface
V.24 (RS-232), DCE
Data Rate
115.2 kbps
Connector
9-pin, D-type, female
Diagnostics
Loopbacks
• E1/T1 local loopback
• E1/T1 remote loopback
Statistics
E1/T1
As per G.826 and RFC 2495
Ethernet
As per RFC 2819
Receive Buffer
Indication
Overflow, underflow, sequence error
Alarm Relay
Dry Contact
Via pin 6, pin 7 and pin 8 of the EXT CLK connector
Indicators
General
PWR (green) – Power
ALM (red/yellow) – Alarm
EXT CLK (red/green) – External clock status
E1
E1 SYNC (red/green) – E1 synchronization
T1
T1 SYNC (red/green) – T1 synchronization
Ethernet
LINK/ACT (green) – Link/activity status
Power
AC/DC Source
100–240 VAC or -40 to -72 VDC
Power Consumption
15W max
Physical
Height
43.7 mm / 1.7 in
Width
240 mm / 9.4 in
Depth
170 mm / 6.7 in
Weight
0.5 kg / 1.1 lb
Environment
Temperature
0 to 50°C/32 to 122°F
Humidity
Up to 90%, non-condensing