Specifications
Installation and Operation Manual Chapter 4 Configuration
IPmux-8/16 Ver. 6.00 Configuring IPmux-8/16 for Operation 4-15
Uplink fail Alarm Behavior (Notification sent to the E1 side if Ethernet link
fails)
Cond (Conditioning code notification. The code pattern is selected via
Cond. Data Pattern parameter.)
AIS (alarm indication signal)
Idle Code (Code transmitted to fill unused timeslots in the E1 frames):
00 to ff.
Signaling Mode
CAS Enable (CAS is enabled)
CAS Disable (CAS is disabled)
Cond. Data Pattern (Conditioning pattern transferred in timeslots toward
the IP path when loss of signal, loss of frame or AIS is detected at the E1
line. Conditioning data pattern is also applied to timeslots toward the E1
line when packet receive buffer overrun, underrun or packet loss occurs. In
unframed mode, AIS is transmitted.): 00–FF
When CAS is disabled, the Cond CAS Pattern parameter is masked.
Cond. CAS (ABCD) Pattern (Conditioning pattern transferred in CAS toward
the IP path when loss of signal, loss of frame or AIS is detected at the E1
line. Conditioning data pattern is also applied to CAS sent toward the E1
line when packet receive buffer overrun, underrun or packet loss occurs.):
1–F.
E1 PHYSICAL LAYER CONFIGURATION
1. Channel Status Enable
2. Transmit Clock Source Loopback
3. Loopback State Disable
4. Rx. Sensitivity -10dB
5. Line Type CRC4 enable
6. UpLink Fail Alarm Behavior Cond.
7. Idle Code 7E
8. Signaling Mode CAS enable
9. Cond. Data Pattern FF
A. Cond. CAS (ABCD) Pattern 01
ESC. Exit
Current Slot/Channel is 4 /1
Select item from the menu.
Figure 4-9. E1 Physical Layer Configuration Menu