Specifications

Chapter 4 Configuration Installation and Operation Manual
4-14 Configuring IPmux-8/16 for Operation IPmux-8/16 Ver. 6.00
Configuring E1 Interface
IPmux-8/16 supports up to 8 or 16 E1 links. Each E1 interface must be configured
individually.
Path: Main > Configuration > Physical Layer Configuration > Slot # 3/4 >
Channel #1–4 or Channel #1–8.
To configure E1 interface:
1. Follow the path above to access the E1 Physical Layer Configuration menu
(
Figure 4-9).
2. From the E1 Physical Layer Configuration menu, configure the following:
Channel Status
Enable (E1 link is enabled)
Disable (E1 link is disabled)
Transmit Clock Source
Adaptive (Adaptive clock regeneration)
Loopback (E1 recovered Rx clock is used as the Tx clock)
Internal (Tx clock is received from an internal oscillator)
External (Tx clock is received from the external clock input)
Loopback State (Controls activation of diagnostic loopbacks, see Diagnostic
Loopbacks in Chapter 6 for detailed loopback function explanation)
Internal (Internal loopback is activated)
External (External loopback is activated)
Disable (All loopbacks are deactivated)
Rx sensitivity (Maximum attenuation of the receive signal that can be
compensated for by the interface receive path)
-10 dB
-32 dB
Line Type (E1 framing mode)
Unframed (Framing is not used)
CRC4 Enable (G.704 framing, CRC-4 function enabled)
Framed G.704 CRC4 (G.704 framing, CRC-4 function disabled)
The following parameters are masked when the line type is set to unframed:
UpLink Fail Alarm Behavior
Idle Code
Signaling Mode
Cond. Data Pattern
Cond. CAS (ABCD) Pattern.
Note