Specifications
Installation and Operation Manual Chapter 4 Configuration
IPmux-8/16 Ver. 6.00 Configuring IPmux-8/16 for Operation 4-9
ASCII Terminal Configuration
1. Display Mode Color
2. Baud Rate [bps] 19200
3. Change Password
4. Hard flow ctrl (RTS/CTS) Off
5. 15 Min. Timeout On
ESC. Exit
+--------------------------------------------------+
|Notice: Change the Baud Rate of the ASCII Terminal|
|after changing and saving of new Baud Rate data! |
+--------------------------------------------------+
Select item from the menu:_
Figure 4-5. ASCII Terminal Configuration Menu
Configuring Out-of-Band Management Port
IPmux-16 supports 10BaseT port for out-of-band management, which has to be
configured at the physical layer.
Path: Main > Configuration > OOB MNG Physical Layer Configuration.
To configure out-of-band management port:
1. Follow the path above to access the OOB Physical Layer Configuration menu.
2. From the OOB Physical Layer Configuration menu, select Default Type and
choose default type of the out-of-band management port (10BaseT full duplex
or 10BaseT half duplex).
4.2 Configuring IPmux-8/16 for Operation
The recommended configuration procedure for IPmux-8/16 operation includes the
following stages:
• Configuring Ethernet and TDM interfaces at the physical level
• Creating bundles by allocating timeslots to them timeslots
• Directing the bundles defined above to remote IPmux unit.
Configuring IPmux-8/16 at the Physical Level
The TDM (E1, T1, E3, T3, channelized T3) and Ethernet interfaces of IPmux-8/16
must be configured at the physical level.