Specifications
Installation and Operation Manual Chapter 3 Operation
IPmux-8/16 Ver. 6.00 Configuration Alternatives 3-9
Configuration Physical Layer Configuration Ethernet Configuration
Ethernet Physical Layer Configuration
Bridge Configuration
VLAN Configuration
1. General Configuration
2. Physical Layer Configuration
3. Timeslots Configuration
4. Bundle Connection
Configuration
5. IP Support
6. Ethernet Redundancy
7. Protection Switching
Configuration
8. Configuration Summary
9. OOB MNG Physical Layer
Configuration
(IPmux-16 only)
1. Slot #1 - ETH SWITCH UTP
2. Slot #2 - ETHERNET UTP
3. Slot #3 -
4. Slot #4 -
8E1 Balanced
8E1 Balanced
1. LAN Physical Layer
Configuration
2. Bridge Configuration
1. Channel
2. Channel State
3. Auto Negotiation
4. Max Capability Advertised
5. Default type
6. VLAN Tagging
7. Default VLAN ID
8. Default VLAN Priority
9. Rate Limit (kbps)
1. Aging Time
2. Erase MAC Table
3. VLAN Configuration
1. Channel
2. VLAN ID
3. Status
Figure 3-7. Configuration > Physical Layer Configuration (Ethernet Modules)
Configuration Physical Layer Configuration E1 Physical Layer Configuration
T1 Physical Layer Configuration
1. General Configuration
2. Physical Layer Configuration
3. Timeslots Configuration
4. Bundle Connection
Configuration
5. IP Support
6. Ethernet Redundancy
7. Protection Switching
Configuration
8. Configuration Summary
9. OOB MNG Physical Layer
Configuration
(IPmux-16 only)
1. Slot #1 - ETH SWITCH UTP
2. Slot #2 - ETHERNET UTP
3. Slot #3 -
4. Slot #4 -
8E1 Balanced
8T1
1. Channel Status
2. Transmit Clock Source
3. Loopback State
4. Rx. Sensitivity
5. Line Type
6. Uplink Fail Alarm Behavior
7. Idle Code
8. Signaling Mode
9. Cond. Data Pattern
A. Cond. CAS (ABCD) Pattern
1. Channel Status
2. Transmit Clock Source
3. Loopback State
4. Line Type
5. Line Code
6. Line Mode
7. Line Length(feet)/Tx Gain(dB)
8. Uplink Fail Alarm Behavior
9. Restore Time
A. Idle Code
B. Signaling Mode
C. Leased Line
E. CSU Loop
F. Cond. Data Pattern
G. Cond. CAS (AB/ABCD) Pattern
H. Cond. CAS first 2.5sec Pattern
Figure 3-8. Configuration > Physical Layer Configuration (E1 and T1 Modules)
Configuration
Physical Layer Configuration
E3/T3 Physical Layer Configuration
1. General Configuration
2. Physical Layer Configuration
3. Timeslots Configuration
4. Bundle Connection
Configuration
5. IP Support
6. Ethernet Redundancy
7. Protection Switching
Configuration
8. Configuration Summary
9. OOB MNG Physical Layer
Configuration
(IPmux-16 only)
1. Slot #1 - ETH SWITCH UTP
2. Slot #2 - ETHERNET UTP
3. Slot #3 - E3 over Coax
4. Slot #4 - T3 over Coax
1. Channel Status
2. Transmit Clock Source
3. Loopback State
Figure 3-9. Configuration > Physical Layer Configuration (E3 and T3 Modules)