Table 3-4. Default Settings (Cont.)
Type Parameter Default Value
PHYSICAL LAYER CONFIGURATION
(Cont.)
Channelized T3 (External)
Channel Status Enable
Line Type C_Bit
Transmit Clock Source Loopback
Loopback State Disable
Channelized T3 (T1)
Channel Status Enable
Line Type T1-ESF
Restore Time 1 second
Loopback State Disable
Transmit Clock Source Loopback
OOB Management Channel
Default Type 10baseT Full Duplex
IP SUPPORT
IP ToS 0
3.4 Configuration Alternatives
After installation, there are no special operating procedures for IPmux-8/16. Once
it is powered up, the unit operates automatically. The unit operational status can
be monitored constantly.
If required, IPmux-8/16 can be reconfigured. IPmux-8/16 can be managed using
different ports and applications:
Local management via an ASCII terminal connected to RS-232 port. Usually,
preliminary configuration of the system parameters is performed via ASCII
terminal. Once the IPmux-8/16 host IP parameters are set, it is possible to
access it via Telnet or RADview for further configuration.
Remote management from a network management station connected to
CONTROL ETH port. Remote management is performed using Telnet or
RADview, RAD’s SNMP-based network management system.
The following functions are supported by the IPmux-8/16 management software:
Viewing system information
Modifying configuration and mode of operation, including setting system
default values
Monitoring IPmux-8/16 performance
Initiating diagnostic tests
Uploading and downloading software, configuration and user files.