Specifications
Installation and Operation Manual Chapter 2 Installation and Setup
IPmux-8/16 Ver. 6.00 Connecting IPmux-8/16 to Power 2-9
Connecting DC Power
To connect DC power:
• Refer to the DC power supply connection supplement for instructions how to
wire the DC adapters. The DC supplement is provided on the technical
documentation CD supplied with the unit.
Replacing AC or DC Power Supplies
IPmux-8/16 can contain one or two power supply units (AC or DC). They are
located in two slots, PS1 and PS2, in the rear panel. The following instructions
refer to the power supply installation in any unit. These instructions are also valid
for power supply replacement in any unit.
To install/replace the power supplies:
1. Turn off the power switch/switches (red, lit) of the power supply (PS1, PS2) on
the rear panel (see
Figure 2-14).
3A T 250V100-240VAC
TYPE AND RATING OF FUSE.
FIRE, REPLACE ONLY WITH SAME
PROTECTION AGAINST RISK OF
FOR CONTINUED
CAUTION
:
POWER
POWER
-48/600
V
DC-IN
Figure 2-14. Power Supply (DC and AC) Rear Panel
2. Disconnect IPmux-8/16 from mains.
3. AC power supply: Pull out the cable safety lock and disconnect the power
cable.
DC power supply: Remove the cable screws connected to the hex nuts on the
rear panel.
1
3
2
4
PS2PS2
Cable
Safety Lock
Support of
Safety Lock
Figure 2-15. IPmux-8/16 Rear Panel – PS Replacement
4. Pull the black knob in the power supply panel and remove the replaceable
power supply unit (see
Figure 2-15).
5. Remove the new power supply from the package.
6. Slide the new power supply in its slot, and push the black knob until the unit is
firmly in place.
7. Connect the power cable connector to the power supply.