Specifications

Chapter 2 Installation and Setup Installation and Operation Manual
2-8 Connecting IPmux-8/16 to Power IPmux-8/16 Ver. 6.00
PS1
~100 -24 0VAC 3A T 125V
POWER
O
I
~100-240VAC 3A T 125V
POWER
O
I
PS2PS1
CH1
CH5
CH2
CH6
CH3
CH7
CH4
CH8
T3 8E1
1
5
3
7
2
6
SYNC
SYNC
4
8
ETH/UTP/4
ACT ACTACT ACTLINK LINKLINK LI NK1324
ETH/UTP/4
ACT ACTACT ACTLINK LINKLI NK LINK1324
TX RX
Figure 2-13. ALARMS Connector (IPmux-16)
To connect to an external alarm source:
1. Prepare a cable in accordance with the alarm connector pinout given in
Appendix A.
2. Connect IPmux-8/16 to an external alarm device, such as a buzzer, using
prepared cable.
2.9 Connecting IPmux-8/16 to Power
To connect power to IPmux-8/16, refer to the appropriate section below,
depending on your version of the unit (AC or DC).
Interrupting the protective grounding conductor (inside or outside the
instrument) or disconnecting the protective earth terminal can make this
instrument dangerous. Intentional interruption is prohibited.
Before switching ON this instrument and before connecting any other cable,
the protective earth terminals of this instrument (either AC or DC version)
must be connected to the protective ground conductor of the power cord.
Make sure that only fuses with the required rated current and specified type,
2 A T 250V as marked on the IPmux-8/16 rear panel, are used for replacement.
Whenever it is likely that the protection offered by fuses has been impaired,
the instrument must be made inoperative and be secured to prevent any
operation.
Refer also to the sections describing connections of AC and DC mains at the
beginning of the manual.
Connecting AC Power
AC power is supplied to IPmux-8/16 through the 1.5m (5 ft) standard power cable
terminated by a standard 3-prong plug. The cable is supplied with the unit
according to the number of ordered power supplies.
To connect AC power:
1. Verify that the AC outlet is grounded properly. Ensure that the supply voltage is
in the range 100 VAC to 240 VAC.
2. Check that the POWER switch on the rear panel is set to OFF.
3. Connect the power cable to the rear panel connector first and then to the
AC mains outlet.
Warning