Specifications

Installation and Operation Manual Chapter 2 Installation and Setup
IPmux-8/16 Ver. 6.00 Connecting to the TDM Equipment 2-3
PS1
~100 -24 0VAC 3A T 125V
POWER
O
I
~100-240VAC 3A T 125V
POWER
O
I
PS2PS1
8E1
Slot 1
Slot 3
Slot 2
Slot 4
Figure 2-2. IPmux-16 Rear Panel Schematics
Table 2-1 lists the module combinations for IPmux-8/16.
Table 2-1. Module Combinations for IPmux-8/16
Slot 1 Slot 2 Slot 3 Slot 4 Comments
Ethernet module Ethernet module E1/T1 E3/T3/CT3 Load sharing
Ethernet module Ethernet module E3/T3/CT3 E1 Load sharing
Ethernet module Ethernet module E1/T1 or E3/T3/CT3 Empty Redundancy
Ethernet module Ethernet module Empty E1/T1 or E3/T3/CT3 Redundancy
Ethernet module Ethernet module E3/T3/CT3 E3/T3/CT3 Load sharing
Ethernet module Ethernet module E1/T1 E1/T1 Load sharing or
Redundancy
Ethernet module Empty E3/T3/CT3 E1/T1 Not valid
Ethernet module Empty E3/T3/CT3 E3/T3/CT3 Not valid
When combining E1 and T1 modules, the T1 module must be inserted in slot 3.
E3, T3 and CT3 modules always require an Ethernet module.
E3/T3 bundle redundancy is available only when the E3 or T3 modules are
installed in slot 3.
IPmux-8 does not use E3, T3 and CT3 modules.
2.5 Connecting to the TDM Equipment
IPmux-8/16 is connected to the TDM equipment via E1/T1 balanced RJ-45 ports
or E3/T3/CT3 unbalanced BNC ports.
Connecting to the E1/T1 Devices
E1/T1 devices are connected to IPmux-8/16 via balanced RJ-45 ports designated
E1/T1. Unbalanced E1 interface is provided via CBL-RJ45/2BNC adapter cable (see
Appendix A for the connector pinouts and cable wiring diagram).
Notes