Specifications
Chapter 2 Installation and Setup Installation and Operation Manual
2-2 Rear Panel Schematics and Module Combinations IPmux-8/16 Ver. 6.00
2.2 Site Requirements and Prerequisites
IPmux-8/16 is designed for installation as a desktop unit. The RM-ACE-202 or
RM-27 rack mount kits, for installation of IPmux-8/16 in a 19-inch rack, are
supplied with the units.
AC-powered IPmux-8/16 units should be installed within 1.5m (5 feet) of an
easily-accessible grounded AC outlet capable of furnishing the required supply
voltage, in the range of 100 to 230 VAC.
DC-powered IPmux-8/16 units require a -48 VDC power source, which must be
adequately isolated from the mains supply.
Allow at least 90 cm (36 inches) of frontal clearance for operator access. Allow at
least 10 cm (4 inches) clearance at the rear of the unit for cable connections. Make
sure that the ventilation holes are not blocked.
The ambient operating temperature of IPmux-8/16 is 0° C to 50° C (32° F to
122°F), at a relative humidity of up to 90%, non-condensing.
2.3 Package Contents
The IPmux-8/16 package contains the following items:
• IPmux-8/16 unit
• CBL-RJ45/2BNC adapter cable for unbalanced E1 interface
• Power cord for each ordered power supply
• Matching SFP transceiver for 4-port Ethernet module (if ordered)
• CBL-DB9/DB9/NULL cross cable that connects the IPmux-8/16 control port
and an ASCII terminal (DTE) for local management.
• RM-ACE-202 kit for IPmux-8 and RM-27 kit for IPmux-16, containing
hardware for mounting on unit in a 19-inch rack.
2.4 Rear Panel Schematics and Module Combinations
Figure 2-1 and Figure 2-2 illustrate construction of the IPmux-8 and IPmux-16 rear
panels, respectively.
PS2
PS2
PS1
POWER
OI
~100 -24 0VAC 3A T 125V
Slot 3
Slot 1
Slot 4
Slot 2
Figure 2-1. IPmux-8 Rear Panel Schematics