Specifications
Chapter 1 Introduction Installation and Operation Manual
1-30 Technical Specifications IPmux-8/16 Ver. 6.00
ALM
ON (red): Major alarm
ON (yellow): Minor alarm
OFF: No alarm
RX
Blinking: Receiving data
OFF: Data is not received
TX
Blinking: Transmitting data
OFF: Data is not transmitted
LINK
ON: Line is OK
OFF: Line is connected
COLL
Blinking: Collisions occur
OFF: Normal operation, no collisions
Ethernet Port
Indicators
LINK
OFF: Line is not active
ON: Line is OK
ACT
OFF: No activity
ON: A frame is transmitted or received on the line
FDX
OFF: Half-duplex
ON: Full-duplex
100M
OFF: 10 MHz
ON: 100 MHz
E1/T1 Port
Indicators
SYNC
ON: Port is synchronized (no alarm)
OFF: Signal loss, LOF or AIS is detected (local alarm)
Blinks: RDI is detected (remote alarm)
Note: All LEDs are ON (green) after power-up.
Power
IPmux-8
100 to 230 VAC, 55W
-40 to -57 VDC, 75W
IPmux-16
100 to 230 VAC, 75W
-40 to -57 VDC, 75W
Physical
IPmux-8
Height
44 mm (1.7 in)
Width
432 mm (17.0 in)
Depth
350 mm (13.8 in)
Weight
7 kg (15.4 lb)
IPmux-16
Height
66 mm (2.6 in)
Width
432 mm (17.0 in)
Depth
350 mm (13.8 in)
Weight
7.1 kg (15.8 lb)