Specifications

Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics
IPmux-8/16 Ver. 6.00 Monitoring IPmux-8/16 Performance 6-5
Displaying E1/T1 Statistics
E1/T1 statistics refer to the physical status of the E1/T1 traffic reaching the IPmux
from the adjacent E1/T1 device.
The E1 statistics parameters comply with the G.703, G.704, G.804, G706, G732,
and G.823 standards.
The T1 statistics parameters comply with the ANSI T.403, AT&T R62411, G.703,
G.704 and G.804 standards.
Path: > Performance Monitoring > Physical Port Statistics > Slot # 3/4.
To view the E1/T1 connection statistics:
1. From the Main menu, select Performance Monitoring.
2. From the Performance Monitoring menu, select Physical Port Statistics.
3. From the Physical Layer Statistics menu, select Slot # 3 or Slot # 4.
4. Select E1 or T1 channel (14 or 18).
Physical Port Statistics screen for the first E1 or T1 port of the selected
module is displayed (see
Figure 6-3). Table 6-3 explains the E1/T1 statistic
parameters provided by IPmux-8/16.
5. From the Physical Port Statistics menu, select Interval and enter the number of
the 15-minute, which statistics you intend to display (196), or type N or P to
browse the stored interval statistics.
Interval time indication is presented as follows:
Time Since – Time (in seconds) elapsed since the beginning of the
currently active interval.
Start Time – Time and date of the beginning of the stored interval.
The current active interval is always marked as interval 0, the previous interval is
marked as 1 and so on. Whenever a new interval is started, the counters are reset
to zero. The E1/T1 counters cannot be reset manually.
Note