Specifications

Chapter 5 Configuring for a Typical Application Installation and Operation Manual
5-6 Checking the Application IPmux-8/16 Ver. 6.00
To connect IPmux-16 bundles:
1. Display the Bundle Connection Configuration menu (Configuration > Bundle
connection configuration) and configure the following parameters:
DS0 Bundle ID – 1 for a bundle to be routed to IPmux-11 (A)
Destination IP Address – IP addresses of the IPmux-11 (A) host
Next Hop – IP address of the next hop router (if the destination IP address
is not in the same subnet as this IPmux).
Destination Bundle – 1.
2. Leave all other parameters with their default values.
3. Save the changes.
4. Display the Bundle Connection Configuration menu again and configure the
following parameters:
DS0 Bundle ID – 2 for a bundle to be routed to IPmux-11 (B)
Destination IP Address – IP addresses of the IPmux-11 (B) host
Next Hop – IP address of the next hop router (if the destination IP address
is not in the same subnet as this IPmux).
Destination Bundle – 1.
5. Save the changes.
5.4 Checking the Application
Once you have finished configuring all the IPmux units, there are several levels on
which to check the application:
The IPmux Statistics screens
The TDM equipment statistics and functionality.
Step 1 – Using IPmux Statistics
To check the application using the IPmux Statistics screens:
1. Select the Performance Monitoring menu in IPmux-16.
2. Select the Bundle Connection Status menu and verify that the connectivity
status is OK, and that you don’t have any sequence errors, underflows or
overflows rising. Verify this for both bundle 1 and bundle 2.
3. If the connectivity status is not OK (either local or remote failure):
Check that all cables and physical connections on the IP side are OK.
Check that the bundle connection configuration was properly made (enable
the OAM mechanism in order to validate the connection sanity).
Check that the IP addresses and default gateways are configured correctly.