Specifications

Installation and Operation Manual Chapter 4 Configuration
IPmux-8/16 Ver. 6.00 Configuring IPmux-8/16 for Operation 4-31
Configuring Bundle Redundancy for Two Units (with or without TDM Protection)
Figure 4-19 illustrates a two-unit bundle redundancy application (with or without
TDM protection).
Figure 4-19. Bundle Redundancy for Two Units
To configure the primary IPmux-8/16:
1. Define host IP and mask IP addresses for Ethernet module 1.
2. Configure the desired TDM port at the physical layer.
3. Assign timeslots to the primary bundle.
4. Connect the configured bundle to the destination bundle.
Bundle defined as redundant is saved with the Connection Status disabled. Its
connection is enabled automatically after setting the protected switching
configuration.
Enable OAM Connectivity.
Define redundancy type as Primary.
5. Configure the desired protected switching parameters for the bundle.
Set the secondary bundle ID to 0 (None).
To configure the secondary IPmux-8/16:
1. Define host IP and mask IP addresses for Ethernet module 1.
2. Configure the desired TDM port at the physical layer.
3. Assign timeslots to the secondary bundle.
4. Connect the configured bundle to the destination bundle.
Bundle defined as redundant is saved with the Connection Status disabled. Its
connection is enabled automatically after setting the protected switching
configuration.
Enable OAM Connectivity.
Define redundancy type as secondary.
5. Configure the desired protected switching parameters for the bundle.
Set the primary bundle ID to 0 (None).
Configuring IP ToS Support
IPmux-8/16 supports enabling or disabling IP ToS support for all network and
out-of-band Ethernet ports. This setting applies to all TDMoIP packets transmitted
by IPmux-8/16.
Note
Note