Specifications

Installation and Operation Manual Chapter 4 Configuration
IPmux-24 Ver. 1.5 Configuring IPmux-24 for Operation 4-21
Source clock quality (Quality of the adaptive clock used by the device):
Stratum 1/PRC G.811
Stratum 2/Type II G.812
Stratum 3/Type IV G.812
Stratum 3E/Type III G.812
Other/Unknown
The Source Clock Quality parameter is relevant only when the Tx clock source
is set to adaptive or loopback.
In adaptive clock mode only the Stratum 1/PRC G.811 and Stratum 2/Type II
G.812 values are available when the Ethernet network type is set to LAN.
Trail Mode (Enables the end-to-end transfer of TDM OAM (Operation,
Administration, and Maintenance) data in framed mode, when the
payload format is set to V2.
Termination (Trail-extended mode is disabled; the TDM networks
function as separate OAM domains)
Extension (Trail-extended mode is enabled; OAM data is passed
between the TDM networks)
Line type (E1 framing mode):
Unframed G.703 (Framing is not used)
Framed G.704 (G.704 framing, CRC-4 function disabled)
Framed G.704 CRC4 (G.704 framing, CRC-4 function enabled)
Framed MF (CAS enabled, CRC-4 function disabled)
Framed MF CRC4 (CAS enabled, CRC-4 function enabled).
Line Interface (Operating mode of the LIU receive path):
LTU
DSU
Idle Code (Code transmitted to fill unused timeslots in the E1 frames):
0 to ff.
Send Upon Fail (Notification sent to the E1 side if Ethernet link fails):
OOS Code (Out-of-service code)
AIS (Alarm indication signal)
OOS code (Code to be sent to the E1 side if Ethernet link fails): 0ff
OOS signaling (Out-of-service signaling method for the framed MF or
framed MF CRC4 line types only. OOS signal is sent toward the IP path
when loss of signal, loss of frame, or AIS is detected at the E1 line. The
OOS signal is also sent toward the E1 line when packet receive buffer
overrun or underrun occurs.):
Space (Code specified by the Space Signaling Code parameter is sent)
Note