Specifications

Chapter 4 Configuration Installation and Operation Manual
4-20 Configuring IPmux-24 for Operation IPmux-24 Ver. 1.5
Table
4-2. Protection Parameters
Parameter Function Values
Ring Administrative
Status
Administrative status of the redundancy
ring.
Up – Protection ring is operational
Down – Protection ring is not operational
Disabled – Operation of an active
protection ring has been suspended
Default: Down
Keep Alive Tx Time Period of time between two keep-alive
PtP messages
2–100 msec
Default: 13
Keep Alive Drops To
Fall
Number of keep-alive PtP messages not
received from adjacent ring member,
after which IPmux-24 declares link failure
1–10
Default: 3
PTP VLAN ID VLAN ID for point-to-point messages.
This VLAN ID must not be used by other
services in the network.
1–4094
Default: 4001
Mcast VLAN ID VLAN ID for multicast messages. This
VLAN ID must not be used by other
services in the network.
1–4094
Default: 4002
Setting Physical Layer Parameters
Configuring the E1 TDM Interface
The E1 and T1 interfaces of IPmux-24 are configured via the TDM menu.
³ To configure the E1 interface:
1. From the Physical Layer menu, select TDM.
The TDM (E1) menu appears (see
Figure
4-21
).
2. From the TDM (E1) menu, type F to select one of the 4 E1 links that you
intend to configure.
3. From the TDM (E1) menu, configure the following:
Administrative Status:
Up (E1 link is enabled)
Down (E1 link is disabled)
Transmit clock source:
Adaptive (Clock is regenerated from an E1 bundle)
Loopback (E1 recovered Rx clock is used as the Tx clock)
Internal (Tx clock is received from an internal oscillator)
System (System clock is used as the Tx clock)