Specifications
Installation and Operation Manual Chapter 3 Operation
IPmux-24 Ver. 1.5 Configuration and Management Alternatives 3-7
3.4 Configuration and Management Alternatives
If required, IPmux-24 can be reconfigured. The IPmux-24 configuration and
monitoring operations are performed using any of the following tools:
• ASCII terminal connected to supervisory port
• Web-based management system, using a Web browser running on a PC
connected to the network
• RADview, RAD’s SNMP-based management system with a graphical user
interface. See RADview SC/TDMoIP User's Manual for details
• Third-party SNMP-based management systems.
Detailed configuration procedures are given in
Chapter 4
.
The following functions are supported by the IPmux-24 management software
:
• Viewing system information
• Modifying configuration and mode of operation, including setting system
default values
• Monitoring IPmux-24 performance
• Initiating diagnostic tests
• Uploading and downloading software and configuration files.
Working with Terminal
IPmux-24 includes a V.24/RS-232 asynchronous DCE port, designated CONTROL
and terminated in a 9-pin D-type female connector. The control port continuously
monitors the incoming data stream and immediately responds to any input string
received through this port.
The IPmux-24 control port can be configured to communicate at the following
rates: 9.6, 19.2, 38.4, 57.6 or 115.2 kbps.
³ To start a terminal control session:
1. Make sure all IPmux-24 cables and connectors are properly connected.
2. Connect IPmux-24 to a PC equipped with an ASCII terminal emulation
application (for example, Windows Hyper Terminal or Procomm).
3. Turn on the control terminal PC and set its port parameters to 115.2 kbps,
8 bits/character, 1 stop bit, no parity. Set the terminal emulator to ANSI
VT100 emulation (for optimal view of system menus).
Login
To prevent unauthorized modification of the operating parameters, IPmux-24
supports three access levels:
• Superuser can perform all the activities supported by the IPmux-24
management facility.
• Users have read-only access, they cannot change any settings.