Specifications

Installation and Operation Manual Chapter 2 Installation and Setup
IPmux-24 Ver. 1.5 Installing SFP Modules 2-3
For rack mounting instructions, refer to RM-35 installation kit manual
For wall mounting instructions, refer to WM-35 installation kit manual
Refer to the clearance and temperature requirements in
Site Requirements and
Prerequisites
.
2.6 Installing SFP Modules
IPmux-24 uses SFP modules with LC fiber optic connectors.
Third-party SFP optical transceivers must be agency-approved, complying with the
local laser safety regulations for Class 1 laser equipment.
³ To install the SFP modules:
1. Lock the wire latch of each SFP module by lifting it up until it clicks into place,
as illustrated in
Figure
2-1
.
Some SFP models have a plastic door instead of a wire latch.
Figure
2-1. Locking the SFP Wire Latch
2. Carefully remove the dust covers from the SFP slot.
3. Insert the rear end of SFP into the socket, and push slowly backwards to
mate the connectors until the SFP clicks into place. If you feel resistance
before the connectors are fully mated, retract the SFP using the latch wire as
a pulling handle, and then repeat the procedure.
4. Remove the protective rubber caps from the SFP modules.
³ To remove the SFP module:
1. Disconnect the fiber optic cables from the SFP module.
2. Unlock the wire latch by lowering it downwards (as opposed to locking).
3. Hold the wire latch and pull the SFP module out of the Ethernet port.
Note
Warning