Specifications
Chapter 1 Introduction Installation and Operation Manual
1-26 Technical Specifications IPmux-24 Ver. 1.5
Management
Methods
• SNMPv1, SNMPv3
• Telnet
• RADview Service Center TDMoIP (ordered separately)
• ASCII terminal via V.24 (RS-232) DCE port
Diagnostics
Loopbacks
• E1/T1 local loopback
• E1/T1 remote loopback
• T1 Facility Type 1 (FAC1) inband loopback
Statistics
E1/T1
As per G.826 and RFC 2495
Ethernet
As per RFC 2819
Receive Buffer
Indication
Overflow, underflow, sequence error
Alarm Relay
Dry Contact
Via pin 6, pin 7 and pin 8 of the EXT CLK connector
(RJ-45)
Indicators
General
PWR (green) – Power
ALM (red/yellow) – Alarm status
SD (red/green) – External clock status
E1
E1 SYNC (red/green) – E1 synchronization
T1
T1 SYNC (red/green) – T1 synchronization
Ethernet
LINK/ACT (green) – Link/activity status
Power
AC/DC Source
100–240 VAC, 50/60 Hz or 48/60 VDC nominal
(40 to 72 VDC)
DC Source
24 VDC nominal (18 to 36 VDC)
Power Consumption
13W max
Physical
Height
47 mm (1.8 in)
Width
215 mm (8.7 in)
Depth
147 mm (5.8 in)
Weight
0.7 kg (1.5 lb)
Environment
Temperature
IPmux-24: 0°C to 50°C (32°C to 122°F)
IPmux-24/H: -30 to 65°C (-22 to 149°F)
Humidity
Up to 90%, non-condensing