Specifications
Chapter 6 Diagnostics and Troubleshooting Installation and Operation Manual
6-6 Monitoring Performance IPmux-24 Ver. 1.5
Displaying Ethernet Statistics
You can display statistic data for the network and user Ethernet ports.
³ To view the Ethernet statistics:
1. From the Statistics menu, select Bridge.
The Bridge screen appears (see
Figure
6-3
).
2. From the Bridge screen, type F to toggle between network and user
interfaces.
Table
6-2
describes the LAN statistics data.
3. Type C to reset the port counters.
4. Type A to reset counters of all IPmux-24 Ethernet ports.
Monitoring>Statistics>Bridge
Channel > (User1-Eth2)
Frames Received Frames Transmitted
Total Frames: (0) Correct Frames: (0)
Total Octets: (0) Correct Octets: (0)
Oversize Frames (0) Collisions: (0)
Fragments: (0)
Jabber: (0)
Dropped Frames: (0)
CRC Errors: (0)
>
F - forward; C - clear counters; A - clear ALL port counters
ESC-prev.menu; !-main menu; &-exit 1 Mngr/s
Figure
6-3. Ethernet Statistics
Table
6-2. Ethernet Statistics Parameters
Parameter Description
Frames Received
Total Frames The total number of correct frames received. When a valid connection is established the
number should increase steadily.
Total Octets The total number of octets (bytes) received. When a valid connection is established the
number should increase steadily.
Oversize
Frames
Number of frames exceeding the maximum allowed frame size, but are otherwise valid
Ethernet frames (good CRC).
Fragments The number of frames that are shorter than 64 bytes and have an invalid CRC.