Specifications

Chapter 3 Operation IPmux-1/1E Installation and Operation Manual
3-4 Operating Instructions
With Control Terminal
To power up IPmux-1/1E with a control terminal:
1. Make sure all IPmux-1/1E cables and connectors are properly connected.
2. Connect IPmux-1/1E to a PC equipped with an ASCII terminal-emulation
application.
3. Turn on the control-terminal PC and set its default port parameters to
19,200 baud, 8 bits/character, 1 stop bit, no parity. Set the terminal emulator
to ANSI VT100 emulation (for optimal view of system menus).
4. Set the POWER switch, located on the rear panel, to ON.
5. When the initialization and self-test are over, a menu appears displaying
initialization and self-test results. If the self-test is successful, the RDY LED
(Figure 3-1 and Figure 3-2) on the left side of the front panel lights up. If
problems are encountered, refer to Chapter 4 for instructions.
6. Press <Esc> to open the configuration software.
7. Enter your User Name according to your assigned system privileges (either
Supervisor (su) or User and then your Password when prompted (the
factory-set password is xxxxxxxxxx).
The Main menu is displayed (Figure 3-9).
If the password is invalid in three consecutive attempts, the system becomes
inaccessible for 15 minutes.
Login
User Name and Password
To enter as a superuser:
1. Enter su for User Name.
2. Enter xxxxxxxxxx for Password.
This allows you to configure all the parameters of IPmux-1/1E, and to change the
su and user passwords.
To view the unit’s configuration:
1. Enter user for User Name.
2. Enter xxxxxxxxxx for Password.
This does not allow you to make configuration changes.
To set all passwords to the default value (xxxxxxxxxx):
Delete the unit’s configuration through the Configuration screens.
Deleting the unit’s configuration using <Ctrl+A> and choosing 4 in the Boot
menu does not set the password to the default value.
Turning IPmux-1/1E Off
To power off the unit:
Set the rear panel POWER switch to OFF.
Note
Note