Specifications

Chapter 3 Operation IPmux-1/1E Installation and Operation Manual
3-2 Front Panel Controls, Connectors, and Indicators
Table 3-1. IPmux-1 LED Indicators
Name Function
PWR
ON – Unit is powered on
OFF – Unit is powered off
RDY ON – Unit is operating properly
OFF – Self-test is in progress
Blinking – Malfunction is detected
SYNC ON – TDM port is synchronized (no alarm)
OFF (unframed) – Signal loss or AIS detected
OFF (framed) – Signal loss, loss of frame or AIS
detected
Blinking – RDI is detected (remote alarm)
ETH LINK ON – Link is OK
OFF – Link is not active
ETH ACT ON – Frame is being transferred on link
OFF – No activity is detected on the link
ETH 100M ON – 100 Mbps
OFF – 10 Mbps
ETH FDX On: Full-duplex
Off: Half-duplex
®
PWR RDY
ETH
FDX100MACTLINK
IPmux-1E
CONTROL
DCE
SYNC
CH1 CH2
CH4CH3
Figure 3-2. IPmux-1E Front Panel