Specifications
IPmux-1/1E Installation and Operation Manual Appendix E Configuration Menus
Performance Monitoring E-39
E1 models
only
Table E-26. DS0 Bundle Configuration Parameters
Parameter Possible Values Remarks
Timeslot Number E1: Timeslot 0 is always invalid and
timeslot 16 is not valid for fractional with
CAS data format.
T1: Valid timeslots are 1 to 24
Timeslot Current
Status
Free
Set
Frees the timeslot from the bundle
Adds the timeslot to the bundle
Echo Cancellation
Status
Free
Set
Echo cancellation status is only
available if your model supports it
Active Timeslots in
this Bundle
Assigned timeslots (read-only)
Free Timeslots Unassigned timeslots (read-only)
To save the change:
• Type <S>.
IPmux-1 associates the new timeslot with the bundle.
E.11 Performance Monitoring
E1/T1 Statistics
E1 STATISTICS
E1 over UTP
LOS: 0
LOF (Red): 0
LCV: 0
RAI (Yellow): 0
AIS: 0
FEBE: 0
BES: 0
DM: 0
ES: 0
SES: 0
UAS: 0
LOMF: 0
Time Since: sec 7------Valid Intervals 12----
1. Interval 0
ESC. Exit N. Next Inv:
Figure E-41. E1/T1 Statistics Menu
Main Menu
↓
3. Performance
Monitoring
↓
1. E1/T1
Statistics