Specifications
Appendix E Configuration Menus IPmux-1/1E Installation and Operation Manual
E-32 Connection Configuration: Dynamic CAS Mode
Table E-21. Protection Switching Configuration Parameters (Cont.)
Parameter Possible Values Remarks
Force Connection
Disable, Primary,
Secondary
Set a specific bundle to be used as the active bundle
disregarding the redundancy status. No flips are
initiated if this option is active.
Recovery Yes, No Determine whether after performing a redundancy
flip, the unit will try to recover to the primary
bundle. The recovery flip takes place only if the
primary bundle is functioning. When set to NO,
flipping between the bundles occurs only when the
present active bundle fails.
Wait-To-Restore Time 0 to 99 sec Determine a period of time that the unit has to wait
before trying to recover to the primary bundle. This
option is relevant only when Recovery option is
enabled.
For the first 10 seconds after a switch between bundles, switching back is disabled –
even if a threshold is exceeded.
E.7 Connection Configuration: Dynamic CAS Mode
To Configure the Connection:
1. Select 1 to enter the Connection Mode. Use the <Spacebar> to select
Dynamic CAS and then press <Enter>.
For Dynamic CAS: The E1/T1 Signaling Mode must be configured as CAS Enable.
2. Enter the Bundle Connection Configuration data (described later in this
section).
The Bundle Connection Configuration menu for Dynamic CAS Mode differs from
the menu used for Static Mode.
3. Enter the Activation Criterion data (described later in this section).
CONNECTION CONFIGURATION
1. Connection Mode Dynamic CAS
2. Bundle Connection Configuration >
3. Activation Criterion >
ESC. Exit
Figure E-34. Connection Configuration
Note
Main Menu
↓
2. Configuration
↓
3. Connection
Configuration
Note
Note