Specifications
IPmux-1/1E Installation and Operation Manual Appendix E Configuration Menus
Connection Configuration: Static Mode E-31
Protection Switching Configuration
PROTECTION SWITCHING CONFIGURATION
1. Primary Bundle ID Empty!
2. Secondary Bundle ID Empty!
3. Redundancy Type Empty!
4. TDM Fail Time Empty!
5. Event Threshold Window (sec) Empty!
6. Sequence Number Threshold (0=Disable) Empty!
7. Underflow/Overflow Threshold (0=Disable) Empty!
8. Local Fail Time (msec) Empty!
9. Force Connection Empty!
A. Recovery Empty!
B. Wait-To-Restore Time (sec) Empty!
ESC. Exit
Figure E-33. Protection Switching Configuration Menu
Table E-21. Protection Switching Configuration Parameters
Parameter Possible Values Remarks
Primary Bundle ID
1, None
Set the active (primary) bundle
Secondary Bundle ID
1, 2, None
Set the secondary (redundant) bundle
Redundancy Type
1+1
1:1
Set the redundancy mode
TDM Fail Time
Disable, Immediate,
100 msec to 1 sec
Determine the time period during which a detection
of LOS/LOF/AIS alarms will trigger a flip (can also be
configured to Immediate)
Event Threshold Window 1 to 1000 sec Determine for what period of time the unit will
count the error events (SN errors or
underflow/overflows). For each new time window
the error events counter will be reset.
Sequence Number
Threshold
1 to 1000 Determine how many Sequence Error events
counted in the Event Threshold Window will trigger
a flip.
Underflow/Overflow
Threshold
1 to 1000 Determine how many Underflow/Overflow events
counted in the Event Threshold Window will trigger
a flip.
Local Fail Time 0 to 99 sec If during this user-configurable period of time, Local
Fail alarm occurs continuously, a flip is initiated.