Specifications

IPmux-1/1E Installation and Operation Manual Appendix E Configuration Menus
General Configuration E-11
Table E-4. Manager List Parameters
Parameter Possible Values Remarks
Manage IP Address 0.0.0.0. to
255.255.255.255
Sets the Manager IP address
Link Up/Down Trap
On
Off
A Link Up/Down trap will be sent to the manager
if there is a physical failure of the LAN or E1/T1
link
A Link Up/Down trap will not be sent to the
manager if there is a physical failure of the LAN or
E1/T1 link
Alarm Trap
On
Off
The alarm trap informs the manager of the
occurrence of any alarm enabled in the Alarms
Trap Mask screen. It informs the manager of both
entry and exit from an alarm state.
No Alarm Trap will be sent regardless of the Mask
defined in the Alarm Trap Mask screen
VLAN Tagging
Yes, No
See Chapter 1 for an explanation of VLAN tagging.
Yes: set options 4 and 5 on the System
Configuration menu
VLAN ID 0 to 4095
Default: 0
VLAN Priority 0 to 7
Default: 0
Alarm Traps Mask
Each of the IPmux-1/1E alarms can activate a trap toward the NMS. It is possible to
enable/disable the trap operation for each one of the alarms, using the Alarm Trap
Mask screen.
ALARM TRAPS MASK
1. Alarm ID <refer to Manual> 1
2. Trap Status Active
Alarm Active Traps:
Select item from the menu.
Use <Esc> key or keys <1> to <2>
Figure E-15. Alarm Traps Mask Menu
Main Menu
2. Configuration
1. General
Configuration
2. Management
Configuration
3. Alarm Traps
Mask