System information
Chapter 4 Configuring Typical Applications User's Manual
4-2 Configuring the IPmux-11 and IPmux-14 Units RADview-SC/TDMoIP IPmux-11
Certain guidelines are relevant to this application. In general, there are four basic
configuration steps (described below) that need to be followed when deploying
any IPmux unit.
1. IP Configuration – Setting the device host IP address and the manager IP
address.
2. Physical layer configuration – Setting the TDM parameters (line type, clocking,
etc.) according to the application requirements and topology.
3. Creating a circuit via the Service Center.
Table 4-1. Configuration Summary
Device E1 Parameters IP Parameters
Bundle
Parameters
Bundle Connection
IPmux-11
• Transmit clock source:
adaptive
• Line type: Framed G.704
CRC-4 enabled
• CAS: disabled
Host IP address:
172.17.157.11
Bundle 1
Timeslots in
bundle: 1–10
Bundle 1 of IPmux-11
IPmux-14
• Transmit clock source:
Loopback
• Line type: Framed G.704
CRC-4 enabled
• CAS: disabled
Host IP address:
172.17.157.14
Bundle 1
Timeslots in
bundle: 1–10
Bundle 1 of IPmux-14
4.1 Configuring the IPmux-11 and IPmux-14 Units
This section explains how to configure the IPmux units. The configuration
procedure is similar for both units, except for defining different host IP addresses,
different clocking modes and different destination IP addresses for the bundle
connection.
Configuring the Host IP Parameters
The host IP parameters are configured via the terminal application.
To configure the host IP parameters:
1. Display the Host IP menu (Configuration > System > Host IP), and configure
the IP address and mask of the host:
IPmux-11 host IP address – 172.17.157.11
IPmux-14 host IP address – 172.17.157.14
2. Save the changes.