System information

User's Manual Chapter 3 Configuration Management
RADview-SC/TDMoIP IPmux-11 Setting the System Parameters 3-7
To remove an entry from the Manager List:
1. Select a row from the Manager List (
Figure 3-3) and click <Remove>.
A message appears, warning about possible disconnection of the manager.
2. Click <OK>.
Configuring the System Clocks
The System Clocks command enables you to configure the Master and Fallback
clocks that keep the IPmux-11 communications lines synchronized with external
devices. You can also use this command to mark the Clock Quality (Stratum) Level.
To configure the system clocks:
1. Select Configuration > Clocks…
2. The System Clocks Dialog Box appears.
3. Configure the desired parameters and click Set.
Master and Fallback clocks cannot be set to the same port.
Figure 3-6. System Clocks Dialog Box
Table 3-4. System Clocks Parameters
Parameter Possible Values / Remarks
Connect Clock Indicates the current source of the system clock (read only)
Master
Fallback
Master Clock
Source
Adaptive
Internal
Rx
Note