System information

Chapter 3 Configuration Management User's Manual
3-2 Setting the System Parameters RADview-SC/TDMoIP IPmux-11
3.1 Setting the System Parameters
Configuring System Parameters
The System Parameters command enables you to view and set major system
parameters for the IPmux-11 device. You can configure parameters such as the
Default Gateway, DHCP Client Mode, Aging Time, and the Transmit Clock
Source.
To set system parameters for the selected IPmux device:
1. Select Configuration > System Parameters…
The System Parameters dialog box appears. System Parameters differ,
depending on the different port combinations.
Table 3-1 describes the
different system parameters.
2. Configure the desired parameters.
3. Click <Set> to implement the changes.
Figure 3-1. System Parameters Dialog Box
Table 3-1. System Parameters
Parameter Possible Values / Remarks
Default Gateway
IP Address
DHCP Mode DHCP Mode
Enabled, Disabled
Aging Time (sec.) 10..450 (Default is 120)
Transmit Clock Source Source of the transmit clock
Internal: Local clock source is used
External: Recovered from the other interface network and used for data
transmission on this interface
Loopback: Transmit clock recovered from received data
Adaptive: Adaptive clock regeneration
Note: Field is disabled if activated circuit is connected.