Specifications

Chapter 4 Management via the CM-2 Module LRS-24 Installation and Operation Manual
4-12 CM-2 Supervision Terminal Language
Scrolling Values When a field has a limited range of values, the available values are
displayed by scrolling. To scroll, bring the cursor to the desired field, and
then press <F> or <U> to scroll forward, press <B> or <D> to scroll
backward. Press <+> or <–> to scroll to the next or previous
command, for up to 10 commands.
Command evaluation Starts only when the <Enter> key is pressed.
Errors In general, if an error is detected during command evaluation, the
command is not executed. Instead, the module will send an error message
to the terminal. The correct command must then be sent again.
Execution The command is executed only after it is validated.
Index of Commands
Table 4-1 lists the set of commands recognized by the CM-2 module in
alphabetical order.
In addition to the commands listed in Table 4-1, the CM-2 module will recognize
commands addressed to I/O modules that can control directly the supervision
terminal. For information on the commands available for any particular I/O
module, refer to the Installation and Operation Manuals of that module.
Table 4-1. Terminal Command Set Index for CM-2 Module
Command Function/Action
DEF CALL Defines parameters for the dial-up modem.
DEF CRD Defines modem type per slot and connection to remote site
DEF DWL Defines operational parameters or command for Download Software version
DEF HUB Defines parameters of CM-2 SNMP agent and general LRS-24 parameters
DEF MNG Defines list of management stations receiving traps generated by CM-2 module
DEF OPR Defines general management parameters of an I/O module (applicable only to modules which do not
support direct management by terminal or SNMP)
DEF PRM Defines basic operational parameters of an I/O module (applicable only to modules which do not support
direct management by terminal or SNMP)
DEF TRM Defines supervision terminal type
DEF TST Performs test on an I/O module (applicable only to modules which do not support direct management by
terminal or SNMP)
DSP ALM Displays general alarm status of LRS-24
DSP ALT Displays module alarm status (applicable only to modules which do not support direct management by
terminal or SNMP)
DSP HUB Displays modules installed in LRS-24
DEF CFG Displays Auto Config screen
DEF MDL Downloads to the modem
DSP LOG Displays list of alarms for CM-2 module, or for a selected I/O module (applicable only to modules which
do not support direct management by terminal or SNMP)
DSP STT Displays I/O module status and diagnostics (applicable only to modules which do not support direct
management by terminal or SNMP)
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com