Specifications

LRS-24 Installation and Operation Manual Chapter 2 Installation and Setup
Initial Operation and Basic Checks 2-29
Normal Indications
PS Module(s): All the indicators on the panel(s) of the PS module(s) must turn
green to indicate proper operation.
CM-2 Module: The POWER indicator of the module must light up. The TD
and RD indicators may flash (or light steadily) when a management session is
in progress.
On start-up, Mask says IGNORE ALARM FROM REMOTE MANAGEMENT.
The default is MASK ON. You must change configuration to MASK OFF.
Normally, the STAT/ADD display shows the two least significant digits of the
management number assigned to LRS-24. For normal startup, a rotating red
circle is displayed. However, if a problem is detected during the power-up
self-test, you will see a flashing error code (E1 through E9), see Chapter 5
Troubleshooting and Diagnostics.
I/O Module(s): Refer to the Installation and Operation Manual of the
corresponding module.
Power Off
To turn off LRS-24 with CM-2:
1. If an external phantom feed voltage source is connected to LRS-24, turn off
that source (i.e. LRS-PS-FEED).
2. Set the ON/OFF switch(es) of the PS module(s) to OFF.
3. Disconnect the DC power, if applicable.
Troubleshooting
In case a malfunction occurs, perform the following preliminary checks:
If the problem affects all the links:
Check that all the indicators on the panels of the PS modules are green.
If any indicator is red, replace the corresponding PS module.
Check that all the modules are installed properly.
Check that all the cable connections are made in accordance with the
installation plan.
Check that all the communication equipment on the link is operating properly.
If the error code E5 appears on the STAT/ADD display of the CM-2 module,
reconfigure the management parameters of the module in accordance with
Chapter 4. Any other code indicates a technical problem, and the
CM-2 module must be replaced.
Check for proper configuration of the local and remote equipment.
See Mask section (Defining Card Configuration / Defining I/O Module
Operational Parameters).