Specifications

Chapter 3. Operation FOMi-E1/T1 Installation and Operation Manual
3-8 Operating Procedures
STATUS REM
BITRATE
REM. M
INTRF
FO-INTRF
CABLE
TEST
REM
LOC
BITRATE
STATUS
TESTS
LINE CONFIG
DTE CONFIG
ALARM BUFFER
Figure 3-6 STATUS Menu Options
Viewing Active
Alarms
(ALARM BUFFER)
FOMi-E1/T1 contains a buffer which stores the system alarms. When alarms
are stored in the alarm buffer, the ERR LED indicator is set to ON. Once the
alarm buffer is cleared, the ERR LED turns off. For ALARM BUFFER details
see Chapter 4, Troubleshooting and Diagnostics.
Configuring the
Line
(LINE CONFIG)
The LINE CONFIG menu supports the configuration of the line parameters.
Refer to the following table for a complete list of configurable line
parameters.
Table 3-4 LINE CONFIG Menu Options
Menu Options Indicates Parameter Values Description
REM. M
Remote modem
connection
FOM-E1/T1
NEW
Displays remote modem
type
LOC. M
FOM-E1/T1
NEW
Displays local modem type
When you configure a parameter, if both modems are connected and the
management is active, the message WAIT... will be displayed, while the
local modem sends the new settings to the remote modem and receives
acknowledgment. Once the acknowledgment is received, the message
disappears and the new setting is displayed, with an asterisk next to it. If
only the local modem is connected, or the management is not active, you
can configure only the local modem. In such a case, the message LOC
CONFIG ONLY will be displayed on the LCD, for a short period, for each
parameter you set.
If, at the time you try to configure the system, the party on the other side of
the line is already modifying the configuration, the message U R BEING
CONFIG will appear on the LCD and you will not be able to modify the
system.