Specifications

FOMi-E1/T1 Installation and Operation Manual Chapter 3. Operation
Operating Procedures 3-5
BITRATE
CABLE
FO INTERFACE
TESTS
INTERFACE
ALARM BUFFER
MAJOR OPTICAL
MAJOR ELEC
NO MANAGEMENT
LINE CONFIG
REM. M AIS LLB
RLB
BERT
RLB + BERT
LED TEST
TESTS
Figure 3-5 FOMi-E1/T1 Menu Option Menu
Note
If a menu option is left unchanged for more than one minute, the unit
automatically returns to the STATUS menu; if there is an alarm stored in the
ALARM BUFFER, the unit displays the ALARM BUFFER menu.
The six main menus are briefly described in the table below.
Table 3-2 Menu Type Options
Menu
Type
Description
STATUS The STATUS menu enables the user to monitor the current
status of the modem.
ALARM
BUFFER
FOMi-E1/T1 contains a buffer which stores the system alarms.
When alarms are stored in the alarm buffer, the
ERR
LED
indicator is set to
ON
. Once the alarm buffer is cleared, the
ERR
LED turns off. For ALARM BUFFER details see Chapter 4,
Troubleshooting and Diagnostics.
LINE
CONFIG
The LINE CONFIG menu supports the configuration of the
line parameter and allows you to select the mode of
operation to fit to the remote modem type.
DTE
CONFIG
The
DTE CONFIG menu supports configuration of AIS for
both local and remote DTEs.
TESTS The TESTS menu provides the capability for executing several
diagnostic tests on the local and remote modems. For more
information, refer to Chapter 4.
Viewing Modem
Configuration
(STATUS)
The STATUS menu enables the user to monitor the current status of the
modem. Monitoring of either local or remote modem is enabled by
toggling between LOC (local) and REM (remote) modems. The status of a
remote modem can be monitored only if the management is active. Refer
to
Table 3-2 for a complete list of possible modem STATUS options and