Specifications
Chapter 2. Installation & Setup FOMi-E1/T1
Installation & Operation Manual
2-6 Jumper Setting
AC Power Connection
AC power should be supplied to FOMi-E1/T1 through the 5 ft (1.5m)
standard power cable terminated by a standard 3-prong plug
(see Figure 2-2). The cable is provided with the unit.
➤
➤ ➤
➤ To connect AC power to FOMi-E1/T1:
•
Connect the power cable to the connector on the FOMi-E1/T1 rear panel
and then to the mains outlet.
The unit turns on automatically upon connection to the mains.
DC Power Connection
➤
➤ ➤
➤ To connect DC power to FOMi-E1/T1
•
Refer to DC Power Supply Connection Supplement.
Fuse
The fuse is located in an integral-type fuse holder located on the rear panel
(see Figure 2-3) Make sure that only fuses of the required rating, as marked
on the FOMi-E1/T1 rear panel, are used for replacement. Do not use
repaired fuses or short-circuit the fuse holder. Always disconnect the mains
cable before removing or replacing the fuse.
If the fuse protection has been damaged, disconnect the unit from the
power mains and secure it against unintended operation.