Specifications
Chapter 2. Installation & Setup FOMi-E1/T1
Installation & Operation Manual
2-4 Jumper Setting
Figure 2-2 FOMi-E1/T1 Rear Panel, AC Power Connection
Figure 2-3 FOMi-E1/T1 Rear Panel, DC Power Connection
Connecting the Fiber-Optic Cables
Two fiber-optic SC, ST or FC-PC connectors are located on the rear panel
and marked TX and RX.
➤
➤ ➤
➤ To connect the fiber-optic cables:
1. Remove the protective caps from the connectors and store them in a
safe place for later use.
2. Connect the transmit fiber to the connector of the central unit marked
TX and the receive fiber to the connector marked RX.
3. At the remote unit connect the transmit fiber to RX and the receive fiber
to TX.
Connecting the Electrical Cable
The E1, balanced link and T1-link connections are connected via an RJ-45
connector, or two BNC connectors for E1, unbalanced link. The BNC
connectors are designed as OUT and IN. OUT refers to a signal transmitted
from the FOMi-E1/T1 to the attached equipment. IN refers to the
FOMi-E1/T1 input signal.
The
RJ-45 pin connector is used for connection of T1 (see Tables 2-1).