Specifications
Package Contents 2-1
Chapter 2
Installation & Setup
This chapter provides mechanical and electrical installation procedures for
FOMi-E1/T1. If a problem is encountered, refer to Chapter 4 for
troubleshooting instructions.
FOMi-E1/T1 is supplied as a fully assembled standalone unit. FOMi-E1/T1
can be adapted to fit into a 19" rack (to order the rack mount adapter kit,
see Ordering Options on the FOMi-E1/T1 data sheet). See Appendix A for
rack mount adapter installation instructions.
2.1 Site Requirements and Prerequisites
Power
AC-powered FOMi-E1/T1 units should be installed within 1.5m (5 ft) of an
easily accessible, grounded AC outlet capable of furnishing the required supply
voltage of the unit (115 or 230 VAC).
DC-powered FOMi-E1/T1 units require a -48 VDC power source which
must be adequately isolated from the mains supply.
In order to prevent a fire hazard, the (negative) supply line must contain a
suitable fuse or a circuit breaker.
Ambient
Requirements
The ambient operating temperature of FOMi-E1/T1 is 0–50
o
C (32–122
o
F) at a
relative humidity of up to 90%, non-condensing.
Allow at least 90 cm (36 in) of frontal clearance for operating and
maintenance accessibility. Allow at least 10 cm (4 in) clearance at the rear of
the unit for signal lines and interface cables.
2.2 Package Contents
The package of the FOMi-E1/T1 standalone unit includes:
•
FOMi-E1/T1 modem (protected by adequate cushioning)
•
AC power cord or DC power supply connector kit
•
FOMi-E1/T1 Installation and Operation Manual