Technical Specifications 1-5
BERT
The pattern generator sends a standard 511-bit pseudo-random pattern to
the remote unit when the user activates the modem diagnostic. At the same
time, the pattern receiver checks the data received from the remote unit
and compares it with the standard 511-bit pattern.
If errors are detected, the ERR LED indicator flashes or remains ON. The
errors are also displayed on the LCD.
Power
Supply
Jitter
Attenuator
G.703
Interface
Scrambler
AIS Gen.
Descrambler CDP Encoder
CDP Coder
Fiber
Optic
CPU
LCD/PCU
and LEDs
PLL
TX
RX
RX
IN
OUT
AIS Gen.
AIS Det.
TX
BERT
TX
MNG
RX
MNG