Specifications
FOM-E3, FOM-T3 Ver. 1.0 Package Contents 2-1
Chapter 2
Installation and Setup
This chapter describes installation procedures for the standalone FOM-E3 and
FOM-T3 devices.
After installing the unit, refer to
Chapter 3
for the system operation information.
Refer to
Chapter 4
for troubleshooting and diagnostics information.
Internal settings, adjustment, maintenance, and repairs may be performed only
by a skilled technician who is aware of the hazards involved.
Always observe standard safety precautions during installation, operation and
maintenance of this product.
Before installing the product, review
Handling Energized Products
at the
beginning of the manual.
2.1 Site Requirements and Prerequisites
Install AC-powered FOM-E3 and FOM-T3 units within 1.5m (5 ft) of an
easily-accessible grounded AC outlet capable of supplying 100 to 240 VAC.
DC-powered FOM-E3 and FOM-T3 units require a –48 VDC nominal power source,
which must be adequately isolated from the mains supply. To prevent a fire
hazard, a suitable fuse must be installed in the –48 VDC line.
Allow at least 90 cm (36 in) of frontal clearance for operator access and at least
10 cm (4 in) clearance at the rear of the unit for interface cable connections.
The ambient operating temperature of FOM-E3 and FOM-T3 should be 0° to 45°C
(32° to 113°F), at a relative humidity of up to 90%, non-condensing.
2.2 Package Contents
The FOM-E3 or FOM-T3 package includes the following items:
• FOM-E3 or FOM-T3 unit
• Technical Documentation CD
• AC power cord or DC power connector.