INSTALLATION AND OPERATION MANUAL FOM-E3/ETH, FOM-T3/ETH 10/100BaseT over E3/T3 Fiber Optic Modems Version 1.
FOM-E3/ETH, FOM-T3/ETH 10/100BaseT over E3/T3 Fiber Optic Modems Version 1.0 Installation and Operation Manual Notice This manual contains information that is proprietary to RAD Data Communications Ltd. ("RAD"). No part of this publication may be reproduced in any form whatsoever without prior written approval by RAD Data Communications.
Limited Warranty RAD warrants to DISTRIBUTOR that the hardware in the FOM-E3/ETH, FOM-T3/ETH to be delivered hereunder shall be free of defects in material and workmanship under normal use and service for a period of twelve (12) months following the date of shipment to DISTRIBUTOR.
General Safety Instructions The following instructions serve as a general guide for the safe installation and operation of telecommunications products. Additional instructions, if applicable, are included inside the manual. Safety Symbols This symbol may appear on the equipment or in the text. It indicates potential safety hazards regarding product operation or maintenance to operator or service personnel.
Handling Energized Products General Safety Practices Do not touch or tamper with the power supply when the power cord is connected. Line voltages may be present inside certain products even when the power switch (if installed) is in the OFF position or a fuse is blown. For DC-powered products, although the voltages levels are usually not hazardous, energy hazards may still exist.
The maximum permissible current capability of the branch distribution circuit that supplies power to the product is 16A (20A for USA and Canada). The circuit breaker in the building installation should have high breaking capacity and must operate at short-circuit current exceeding 35A (40A for USA and Canada). Before connecting the DC supply wires, ensure that power is removed from the DC circuit. Locate the circuit breaker of the panel board that services the equipment and switch it to the OFF position.
When using shielded or coaxial cables, verify that there is a good ground connection at both ends. The grounding and bonding of the ground connections should comply with the local codes. The telecommunication wiring in the building may be damaged or present a fire hazard in case of contact between exposed external wires and the AC power lines. In order to reduce the risk, there are restrictions on the diameter of wires in the telecom cables, between the equipment and the mating connectors.
FCC-15 User Information This equipment has been tested and found to comply with the limits of the Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Français Mise au rebut du produit Afin de faciliter la réutilisation, le recyclage ainsi que d'autres formes de récupération d'équipement mis au rebut dans le cadre de la protection de l'environnement, il est demandé au propriétaire de ce produit RAD de ne pas mettre ce dernier au rebut en tant que déchet municipal non trié, une fois que le produit est arrivé en fin de cycle de vie.
• Avant la mise en marche de l'équipement, assurez-vous que le câble de fibre optique est intact et qu'il est connecté au transmetteur. • Ne tentez pas d'ajuster le courant de la commande laser. • N'utilisez pas des câbles ou connecteurs de fibre optique cassés ou sans terminaison et n'observez pas directement un rayon laser. • L'usage de périphériques optiques avec l'équipement augmentera le risque pour les yeux.
Français Connexion au courant du secteur Assurez-vous que l'installation électrique est conforme à la réglementation locale. Branchez toujours la fiche de secteur à une prise murale équipée d'une borne protectrice de mise à la terre. La capacité maximale permissible en courant du circuit de distribution de la connexion alimentant le produit est de 16A (20A aux Etats-Unis et Canada).
Declaration of Conformity Manufacturer's Name: RAD Data Communications Ltd. Manufacturer's Address: 24 Raoul Wallenberg St., Tel Aviv 69719, Israel declares that the product: Product Name: FOM-E3/ETH, FOM-T3/ETH conforms to the following standard(s) or other normative document(s): EMC: EN 55022:1998 + A1:2000, A2:2003 Information technology equipment – Radio disturbance characteristics – Limits and methods of measurement.
Quick Start Guide If you are familiar with FOM-E3/ETH and FOM-T3/ETH modems, use this guide to prepare the units for operation. 1. Installing FOM-E3/ETH and FOM-T3/ETH Open the FOM-E3/ETH or FOM-T3/ETH case by releasing the two rear panel screws and sliding out the PCB interior of the unit.
Quick Start Guide Installation and Operation Manual Section Name Description Possible Settings Factory Setting 7 MUL Controls LAN to WAN multicasting ON – Multicast messages from LAN to WAN are blocked OFF – Multicast messages from LAN to WAN are not blocked 8 SCR Note Controls the scrambling of ON – Ethernet frames are scrambled Ethernet frames OFF – Ethernet frames are left unchanged OFF OFF After configuring the Ethernet interface, reset FOM-E3/ETH or FOM-T3/ETH by turning it off and on.
Contents Chapter 1. Introduction 1.1 1.2 1.3 1.4 Overview....................................................................................................................1-1 Versions .................................................................................................................1-1 Power Options ...................................................................................................1-1 Application .............................................................................
Table of Contents ii Installation and Operation Manual FOM-E3/ETH, FOM-T3/ETH Ver. 1.
Chapter 1 Introduction 1.1 Overview FOM-E3/ETH and FOM-T3/ETH are fiber optic modems for transmission of 10BaseT or 100BaseT signals over E3/T3 services via multimode or single mode fiber optic media. Product Options Model Options • FOM-E3/ETH: 10/100BaseT over E3 fiber optic services • FOM-T3/ETH: 10/100BaseT over T3 fiber optic services. Power Options • AC power supply: 100 to 240 VAC • DC power supply: 20 to 72 VDC.
Chapter 1 Introduction Installation and Operation Manual Features Ethernet Interface The Ethernet interface of the FOM-E3/ETH and FOM-T3/ETH modems is a high performance self-learning Ethernet bridge module, fully compatible with IEEE 802.3/Ethernet V.2, IEEE 802.1p standards. It also supports the relevant parts of the IEEE 802.1q standard, enabling VLAN applications. The Ethernet interface provides one LAN connection, which can be either 10BaseT (UTP) or 100BaseT (UTP), both with VLAN tagging support.
Installation and Operation Manual Chapter 1 Introduction Alarms When FOM-E3/ETH or FOM-T3/ETH detects that the bit error rate of the signal received from the optical interface is 10-6 or worse, the modem transmits an "All 1s" signal (AIS) to the optical interface. When an AIS is detected at the optical interface, the modem transparently converts the signal and alerts the user via front panel LEDs and the alarm relay port.
Chapter 1 Introduction 1.3 Installation and Operation Manual Functional Description Figure 1-2 illustrates the FOM-E3/ETH and FOM-T3/ETH functional diagram. Optical Interface CODEC Ethernet Interface TCDP + TNRZ Rx TCDP - Tx TCLK RCDP + RNRZ Tx Rx RCLK RCDP - Oscillator Internal Clock Figure 1-3.
Installation and Operation Manual Chapter 1 Introduction Timing Figure 1-3 shows flow of the clock signals in the FOM-E3/ETH or FOM-T3/ETH unit. The modems support only internal clock, where an on-board crystal oscillator (±25 ppm) serves as the timing source for the system. Alarm Relay FOM-E3/ETH and FOM-T3/ETH feature an alarm port, used for the relay of the alarm conditions (AIS and ERR) by means of Normally Open and Normally Closed dry contacts, using different pins of the DB-9 port connector. 1.
Chapter 1 Introduction Installation and Operation Manual Overhead 30 bits per frame (added to the Ethernet frames when they are sent toward E3/T3 line) Connector RJ-45 Timing Clock Source Internal clock provided by on-board crystal oscillator (±25 ppm) Indicators PWR ON – FOM-E3/ETH or FOM-T3/ETH is powered up OPTICAL ERR ON – Bit error rate of the signal received from the optical interface is 10-6 or worse OPTICAL AIS ON – E3/T3 interface received Alarm Indication Signal ETH LINK ON – LAN
Chapter 2 Installation and Setup This chapter describes installation procedures for the standalone FOM-E3/ETH and FOM-T3/ETH devices. After installing the unit, refer to Chapter 3 for the system operation information. Refer to Chapter 4 for troubleshooting and diagnostics information. Internal settings, adjustment, maintenance, and repairs may be performed only by a skilled technician who is aware of the hazards involved.
Chapter 2 Installation and Setup 2.3 Installation and Operation Manual Installation and Setup FOM-E3/ETH and FOM-T3/ETH are standalone devices intended for tabletop or 19-inch rack installation. They are delivered completely assembled. No provision is made for bolting the unit on the tabletop. To install FOM-E3/ETH or FOM-T3/ETH: 1. Determine the required configuration of FOM-E3/ETH or FOM-T3/ETH according to your application, and set the internal jumpers and switches accordingly. 2.
Installation and Operation Manual Chapter 2 Installation and Setup Caution FOM-E3/ETH and FOM-T3/ETH contain components sensitive to electrostatic discharge (ESD). To prevent ESD damage, avoid touching the internal components. Before moving jumpers, touch the FOM-E3/ETH or FOM-T3/ETH frame. To open the FOM-E3/ETH or FOM-T3/ETH case: 1. Disconnect all the cables connected to FOM-E3/ETH or FOM-T3/ETH. 2. Release the two rear panel screws and use them as levers to slide out the PCB interior of the unit.
Chapter 2 Installation and Setup Installation and Operation Manual Table 2-1. Main Board Jumper Settings Jumper Description Values Factory Setting AIS, JP5 Controls the AIS transmission ON – AIS is transmitted OFF – AIS is not transmitted ON Note The FOM-E3/ETH and FOM-T3/ETH main boards contain an additional jumper, JP1, which is factory-set to INT and must not be moved by the user.
Installation and Operation Manual Chapter 2 Installation and Setup Section Name Description Possible Settings Factory Setting 7 MUL Controls LAN to WAN multicasting ON – Multicast messages from LAN to WAN are blocked OFF – Multicast messages from LAN to WAN are not blocked 8 SCR Controls the scrambling of ON – Ethernet frames are scrambled Ethernet frames OFF – Ethernet frames are left unchanged OFF OFF Closing the Case Once you finish the internal settings, you have to close the FOM-E3/ETH
Chapter 2 Installation and Setup Installation and Operation Manual The fiber optic interface of the FOM-E3/ETH or FOM-T3/ETH units terminate in ST, FC or SC connectors, designated TX and RX. To connect the fiber optic interface: 1. Remove the protective caps from the connectors and store them in a safe place for later use. 2. Connect the transmit fiber to the connector marked TX and the receive fiber to the connector marked RX. 3.
Installation and Operation Manual Chapter 2 Installation and Setup Connecting the AC Power AC power should be supplied to FOM-E3/ETH and FOM-T3/ETH through the 1.5m (5 ft) standard power cable terminated by a standard 3-prong plug (see Figure 2-3). The cable is provided with the unit. To connect AC power: • Connect the power cable first to the connector on the FOM-E3/ETH or FOM-T3/ETH rear panel, and then to the mains outlet.
Chapter 2 Installation and Setup 2-8 Installation and Setup Installation and Operation Manual FOM-E3/ETH, FOM-T3/ETH Ver. 1.
Chapter 3 Operation This chapter describes the FOM-E3/ETH and FOM-T3/ETH controls and indicators, and their functions, explains the units' operating procedures. 3.1 Front Panel Indicators and Controls Figure 3-1 shows the front panel of FOM-E3/ETH. Table 3-1 lists the functions of the FOM-E3/ETH LED indicators, located on the front panel. OPTICAL ERR PWR ETH AIS LINK ACT 100 Figure 3-1. FOM-E3/ETH Front Panel Table 3-1.
Chapter 3 Operation Installation and Operation Manual 3.2 Operating Instructions Turning On FOM-E3/ETH and FOM-T3/ETH start operating as soon as they are connected to the power source. The PWR LED turns ON and remains lit as long as the units are connected to the mains. Normal Operating Instructions The following LEDs conditions are observed during the normal operation: • PWR is ON. • LINK and ACT are ON to indicate data transfer over the Ethernet link.
Chapter 4 Diagnostics and Troubleshooting 4.1 Alarm Relay FOM-E3/ETH and FOM-T3/ETH include a dry contact alarm relay port supported via 9-pin connector for major and minor alarms. • • Major alarms are initiated bit error rate at the fiber optic interface is 10-6 or worse. Minor alarms occur when an Alarm Indication Signal is received at the fiber optic interface. The dry contact port operates as Normally Open or Normally Closed, using different pins of the alarm relay port connector (see Figure 4-1).
Chapter 4 Diagnostics and Troubleshooting 4.2 Installation and Operation Manual Troubleshooting Instructions In case a problem occurs, refer to Table 4-1 for the troubleshooting procedures. Perform the actions listed under Corrective Measures in the order given in the table, until the problem is corrected. Table 4-1. Troubleshooting Chart Trouble Symptoms Probable Cause Corrective Measures PWR indicator is OFF No AC power Verify that the power outlet is providing the required power.
24 Raoul Wallenberg Street, Tel Aviv 69719, Israel Tel: +972-3-6458181, Fax +972-3-6483331, +972-3-6498250 E-mail: erika_y@rad.com, Web site: http://www.rad.com Customer Response Form RAD Data Communications would like your help in improving its product documentation. Please complete and return this form by mail or by fax or send us an e-mail with your comments. Thank you for your assistance! Manual Name: FOM-E3/ETH, FOM-T3/ETH Ver. 1.
Error Report Type of error(s) or problem(s): Incompatibility with product Difficulty in understanding text Regulatory information (Safety, Compliance, Warnings, etc.) Difficulty in finding needed information Missing information Illogical flow of information Style (spelling, grammar, references, etc.) Appearance Other Please list the exact page numbers with the error(s), detail the errors you found (information missing, unclear or inadequately explained, etc.
Publication No. 149-200-12/08 Order this publication by Catalog No. 803292 International Headquarters 24 Raoul Wallenberg Street Tel Aviv 69719, Israel Tel. 972-3-6458181 Fax 972-3-6498250, 6474436 E-mail market@rad.com North America Headquarters 900 Corporate Drive Mahwah, NJ 07430, USA Tel. 201-5291100 Toll free 1-800-4447234 Fax 201-5295777 E-mail market@rad.com www.rad.