Specifications
Installation and Operation Manual Chapter 5 Configuring a Typical Application
RICi-E3, RICi-T3 Ver. 1.0 Configuring the Physical Ports 5-5
Configuring the Ethernet Port
To configure the Ethernet port parameters:
1. Navigate to the Ethernet menu:
Main Menu > Configuration > Physical Ports > Ethernet
2. Configure the Ethernet parameters as specified below:
Administrative Status: Up
Autonegotiation: Enable
Flow Control: Enable
Max Capability Advertised: 100BaseTx.
3. Select Save.
Configuring the Bridge Parameters
To configure the bridge parameters:
1. Navigate to the Bridge menu:
Main Menu > Configuration > Applications > Bridge
2. Configure the Bridge parameter values as specified below:
Forwarding Mode: Transparent
Aging Time: 300.
3. Select Save.
Building the MAC Table
To configure the static MAC table:
1. Navigate to the Static MAC Table menu:
Main Menu > Configuration > Applications > Bridge > Static MAC table
2. Press <A>to add a static MAC address.
The Static MAC Table display changes, entering the Add mode.
3. In Add mode, perform the following:
Select MAC Address, and enter a new MAC address.
Select Receive Bridge Port, and choose a RICi-E3, RICi-T3 interface this
MAC address will be attached to.
Select Save to save the MAC address.
Press <Esc> to return to the Static MAC Table.