Specifications

Installation and Operation Manual Chapter 5 Configuring a Typical Application
RICi-E3, RICi-T3 Ver. 1.0 Configuring the RICi-E3, RICi-T3 System Parameters 5-3
Connecting DC Power
A special IEC 60320 adapter for -48/-60 VDC power supply is available. 24 VDC
RICi-E3, RICi-T3 units have a terminal block DC inlet and adapter supplied with the
unit.
To connect DC power:
Refer to the DC power supply connection supplement for instructions how to wire
the DC adapters, and to the
Handling Energized Products
section.
5.3 Configuring the RICi-E3, RICi-T3 System Parameters
Make sure that the RICi-E3, RICi-T3 unit is properly installed and connected to an
ASCII terminal.
Configuring Parameters via ASCII Terminal
To configure the RICi-E3, RICi-T3 system parameters:
1. Configure an ASCII terminal as follows:
Baud rate: 115200 bps
one start bit, eight data bits, no parity, one stop bit, no flow control, and
VT100 emulation.
2. Connect the terminal to the CONTROL port at the rear panel.
3. Press <Enter> to initiate the control session and then enter the user name
and password. The default user name and password for the superuser are as
follows:
User Name: su (lower case)
Password: 1234
4. Configure the system parameters necessary:
Main Menu > Configuration > System > Management > Host IP
Host IP Address: Define the host IP address 123.123.123.123
Host IP Mask: 255.255.255.0
Default Gateway: 123.123.321.321